| AIWWTP Disinfection Construction |
| New liquid disinfection hypochlorite system and the new dechlorination sodium bisuphite system (inclusive of concrete containment area, installation of associated chemical storage, piping, and metering systems)in two separate locations within the AIWWTP. | - 3rd/4th quarter |
| AIWWTP Disinfection Equipment Pre-purchase |
| FRP chemical storage tanks, metering pumps, and in-channel static mixers | - 3rd/4th quarter |
| Annacis WWTP FTV #3 Cleaning (and Coating of Vessel) |
| Clean FTV #3 & standpipe, provide confined space entry and leak test services, and possibly coat the vessel | - 3rd quarter |
| Boundary Road Main No.5 |
| Boundary Road Main No. 5, Phase 3, Installation of 3,000m of 1800mm diameter steel pipe in Vancouver and Burnaby | - 1st quarter - March |
| Boundary Road Main No. 5 - Patterson Avenue Section - Supply of 500m of 1800mm diameter steel pipe and butterfly valves. | - 4th quarter |
| Construction |
| 25th Avenue Main Replacement (Phase 2)- supply and installation of 1450m of 600mm dia. ductile iron pipe and fitting along 25th Ave., between Carolina St. and Dumfries St. in Vancouver | - 3rd quarter |
| Boundary Road Main No. 5 - Phase 3 (East) - Installation of 1670 m of 1800mm dia. steel pipe in Burnaby | - 3rd quarter |
| Jervis Forcemain Planetarium Section - Installation of 1450 m of 1200mm dia. steel pipe from Vanier Park to Pine Street in Vancouver | - 3rd quarter |
| Jervis Forcemain - Extension to Eighth Avenue (Tunnel Section) - Installation of 450 m of rock tunnel on Pine Street in Vancouver | - 3rd quarter |
| South Nicomekl Trunk Sewer Rehabilitation - Installation of 125 m of 600mm-750mm CIPP in the City of Langley | - 3rd quarter |
| Coquitlam Interceptor Rehabilitation - Installation of 610 m of 1350mm CIPP in Coquitlam | - 3rd quarter |
| 25th Avenue Main, supply and install 3.1km of 600mm ductile iron pipe and fittings. On 25th Avenue between Cambie Street and Kingsway, Vancouver | - 2nd quarter - April |
| Jervis Forcemain Planetarium Section - Installation of 1700 m of 1200mm diameter steel pipe from Vanier Park to Pine Street, Vancouver | - 2nd quarter - April |
| Jervis Forcemain - Extension to 8th Avenue. Installation of 900m of rock tunnel with pipe installation on Pine Street, Vancouver | - 4th quarter - October |
| Highbury Interceptor - CIPP installation of a 260m of 1725 mm diameter inverted siphon at north end of Crown Street under the Fraser River in Vancouver. | - 2nd quarter |
| Screening System Upgrade and Trickling Filter Pipe - NWL | - 3rd quarter |
| Construction/Equipment |
| CLF Road upgrade - S. access road | - 3rd quarter |
| MTS Painting | - 3rd quarter |
| MTS Floor Repair | - 4th quarter |
| NSTS Parking Lot | - 4th quarter |
| NSTS S-Curve Project | - 4th quarter |
| Consulting Services |
| Weigh Scale Consultant - 3 yr contract | - 4th quarter |
| Coquitlam UV Disinfection Project |
| UV disinfection equipment (up to 10 medium pressure units) | - 3rd quarter |
| Power Transformers (two 2.5 MVA units) | - 3rd quarter |
| Generators (two 1,000 kW units) | - 4th quarter |
| Diesel fuel storage tank and fuel polishing equipment | - 4th quarter |
| Large diameter valves (in order of 14 ranging up to 2700 mm Dia) | - 4th quarter |
| UPS equipment (10 kVA) | - 4th quarter |
| MCC equipment | - 4th quarter |
| LV power distribution equipment | - 4th quarter |
| HV switchgear | - 4th quarter |
| Ozone generating equipment and power supply unit | - 3rd quarter |
| Douglas Road Main No.2 |
| Douglas Road Main No. 2. Phase 2, Installation of 1.6 km 1500 mm steel pipe and cross over chamber construction. 6th Street in Burnaby | - 1st quarter |
| Douglas Road Main No. 2, Phase 3, Supply of 2.1 km of 1500mm steel pipe | - 4th quarter |
| Electrical Installation |
| Boundary Main No. 5 North Valve Chambers Electrical Installation | - 1st quarter - March |
| Engineering |
| Sludge Control Building #1 Refurbishment | - 2nd quarter |
| Engineering Consulting Services |
| CLF Comprehensive Engineering Consulting Services | - 4th quarter |
| Installation |
| Barnston Island Main Valve Chamber Metering | - 2nd quarter |
| Installation of Kiosk and Flowmeter |
| Sapperton Main No. 2 - North Road & Brunette Flowmeter Addition | - 2nd quarter |
| Central Park Main - Imperial & Royal Oak Valve Chamber Metering | - 2nd quarter - June |
| Kiosk Relocation |
| Sherbrooke & Brunette - Kiosk Relocation | - 2nd quarter |
| Lions Gate WWTP Admin Bldg Roofing |
| Possibly construct roof repairs in 2008 after admin building refurbishment complete | - 4th quarter |
| Lions Gate WWTP HVAC Upgrade |
| Supply and install HVAC equipment for some of all of these areas: Sludge Control Building 3, Boiler Room, and/or Sludge Control Building 2 | - 3rd/4th quarter |
| Maintenance Shop Canopy at AIWWTP |
| Construction of canopy on the north side of Maintenance Building for cart storage. | - 3rd quarter |
| Modification-Electrical Work |
| Newton Secondary Disinfection Station Hypochlorite Tank Modification - Electrical Work | - 2nd quarter |
| NW Langley WWTP Headworks Upgrade |
| Replace and install various equipment in the headworks section (includes mechanical, electrical, and civil/structural work). | - 3rd quarter |
| Pipe and Valve Supply |
| Sapperton Pump Station - supply of sewage pumps | - 4th quarter |
| Sapperton Pump Station - supply of sewage pumps. | - 2nd quarter - May |
| Purchase of B-Trains |
| B-Trains | - 1st quarter - February |
| Scada Link - New Kiosk |
| Meter 18 (Capilano & Welch) Scada Link - New Kosk | - 2nd quarter |
| Service Contract |
| WTEF Stack Testing | - 4th quarter |
| CLF Groundwater Monitoring Contract - 3 yr contract | - 4th quarter |
| South Shaft Access Imporvements |
| Installation of platforms in South Shaft (material being purchased this year) | - 3rd quarter |
| Spanish Banks Pump Station |
| Spanish Banks Pump Station 12KV Load Break Switch Replacement | - 1st quarter - March |
| Steel Pipe and Valve Supply |
| Douglas Road Main No. 2 (Phase 3) - Supply of 2100 m of 1500mm steel pipe and butterfly valves | - 4th quarter |
| Boundary Road Main No. 5 - Patterson Ave. Section - Supply 500 m of 1800mm dia. steel pepe and butterfly valves | - 4th quarter |
| 16th Ave. Main- Supply of 2100 m of 750mm steep pipe and butterfly valves. | - 4th quarter |
| Supply and Delivery |
| Supply and Delivery of MNotor Control Centres - Iona Island WWTP. | - 2nd quarter |
| Supply and Installation |
| Supply and installation of new guardhouse and Security storage building - Seymour Falls Dam Seismic Upgrade Project | - 2nd quarter |
| Van ITS Reservoir East Wall Concrete Repairs |
| Van Hts Reservoir east wall concrete repairs inside Van Hts Pump Station | - 3rd quarter |
| Whell Loader Replacement |
| CCRF Wheel Loader - Replacement | - 1st quarter - February |